$2.14

DETAILS:

The ICM350 Defrost Board is a 3-in-1 replacement board for Carrier HK32EA001, HKEA003 and HK32EA008 boards. Special circuitry helps reduce noise disturbances when entering and exiting the defrost sequence on the 003 and 008 applications.
Features:
  • Adjustable 30, 60, 90, and 120 minute timing sequences
  • Speedup jumper for quicker testing and troubleshooting
  • Brownout monitoring
  • Microcontroller precision timing
  • Time and temperature termination
  • Quiet Shift : Reduces noise disturbance when entering and exiting the defrost sequence (HK32EA003 & HK32EA008)
  • 5 minute anti short cycle delay (HK32EA003 & HK32EA008)
  • Optional random start timer (HK32EA003 & HK32EA008)

SPECIFICATIONS:

  • Voltage:18-30 VAC
  • Frequency: 50/60 Hz
  • Power Consumption: 1 Watt maximum
  • Current Draw: 300mA maximum
  • Maximum Defrost Sequence: 10 minutes
HK32EA001:
Speedup defrost timing sequence:
Specified Time IntervalSpeedup Equivalent Time Interval
10 minute maximum defrost2.3 seconds
30 minute timing sequence7 seconds
60 minute timing sequence14 seconds
90 minute timing sequence21 seconds
120 minute timing sequence28 seconds
HK32EA003/HK32EA008:
  • Speedup defrost timing sequence: 5 seconds (active upon release)
  • ASC delay: 5 minutes at startup and between heating calls
  • Forced DFT sequence: 30 seconds
  • Random start timer: 0-30 seconds
  • Quiet shift compressor delay: 30 seconds (HK32EA003), 70 seconds (HK32EA008)

DETAILS:

The ICM350 Defrost Board is a 3-in-1 replacement board for Carrier HK32EA001, HKEA003 and HK32EA008 boards. Special circuitry helps reduce noise disturbances when entering and exiting the defrost sequence on the 003 and 008 applications.
Features:
  • Adjustable 30, 60, 90, and 120 minute timing sequences
  • Speedup jumper for quicker testing and troubleshooting
  • Brownout monitoring
  • Microcontroller precision timing
  • Time and temperature termination
  • Quiet Shift : Reduces noise disturbance when entering and exiting the defrost sequence (HK32EA003 & HK32EA008)
  • 5 minute anti short cycle delay (HK32EA003 & HK32EA008)
  • Optional random start timer (HK32EA003 & HK32EA008)

SPECIFICATIONS:

  • Voltage:18-30 VAC
  • Frequency: 50/60 Hz
  • Power Consumption: 1 Watt maximum
  • Current Draw: 300mA maximum
  • Maximum Defrost Sequence: 10 minutes
HK32EA001:
Speedup defrost timing sequence:
Specified Time IntervalSpeedup Equivalent Time Interval
10 minute maximum defrost2.3 seconds
30 minute timing sequence7 seconds
60 minute timing sequence14 seconds
90 minute timing sequence21 seconds
120 minute timing sequence28 seconds
HK32EA003/HK32EA008:
  • Speedup defrost timing sequence: 5 seconds (active upon release)
  • ASC delay: 5 minutes at startup and between heating calls
  • Forced DFT sequence: 30 seconds
  • Random start timer: 0-30 seconds
  • Quiet shift compressor delay: 30 seconds (HK32EA003), 70 seconds (HK32EA008)